PREMIER BUILDING SYSTEMS, LLC
18504 Canyon Road East
Puyallup, Wa 98375
OFFICE (253) 846-6033

DRAWN BY: NL
DATE: 4-16-2026
REVISIONS
5.
3.
4.
2.
1.
# DATE TYPE
REVISION TYPES
C-REV: Customer Revision
E-REV: Engineer Revision
P-REV: Premier Revision
10x12 POD

12100 Wilshire Blvd Ste 800
Los Angeles, CA 90025
916-261-3974
PBS PROJECT NO:
20260212-0001
DRAFTER
PROJECT MANAGER
NL
6.
4-27-26 C-REVNL
PREMIER BUILDING SYSTEMS, LLC
18504 Canyon Road East
Puyallup, Wa 98375
OFFICE (253) 846-6033

SIP DELIVERY
WE DO OUR BEST TO SHIP SIPS SEQUENCED PER CLIENT REQUEST. HOWEVER, WE MUST ALSO MAKE BEST USE
OF THE AVAILABLE SPACE ON EACH SHIPMENT, AND ENSURE THAT THE LOAD IS SAFE FOR TRANSPORTATION.
BEAR IN MIND THAT ALL SIPS HAVE MARKINGS WHICH MAKE FOR A SMOOTH IDENTIFICATION PROCESS. IF
YOU DESIRE A SPECIAL LOADING PLAN, THAT REQUEST, AND LAYOUT, MUST BE MADE CONCURRENT WITH THE
RETURN OF THE SIGNED SIP SHOP DRAWINGS AND MAY BE SUBJECT TO AN ADDITIONAL FEE DUE TO IMPACT
ON YIELD, AND THE TOTAL NUMBER OF SHIPMENTS REQUIRED. SIPS ARE FABRICATED AT 4' & 8' WIDTHS AND
UP TO 24' LENGTHS. 6' FORKS ARE REQUIRED FOR 8' WIDE SIPS (REFER TO THE CONTRACT OF SALE FOR MORE
INFORMATION OR ASK PBS FOR A DELIVERY INFORMATION SHEET).
APPROVED AS DRAWN
APPROVED WITH REVISIONS AS NOTED
REVISE & RESUBMIT
CUSTOMER'S SIGNATURE
PLEASE
SIGN HERE
DATE
PREMIER SIPS WALL TYPE
EPS A3.50A ZB
4
THIS PROJECT UTILIZES THE FOLLOWING SIP TYPES
LIST OF DRAWINGS
10x12 POD
CUSTOMER CHECK LIST
TWO ROUNDS OF REVISIONS/EDITS ARE INCLUDED IN THE INITIAL PRE-PRODUCTION SERVICES PORTION OF
THE PBS ESTIMATE. ADDITIONAL REVISIONS MAY INCUR ADDITIONAL FEES.
WHEN YOU HAVE FINISHED VERIFYING THE SIP SHOP DRAWINGS AND HAVE MADE ANY
CHANGES/CORRECTIONS, COPY THOSE CHANGES TO THE SIP SHOP DRAWINGS AND SEND BACK TO PBS FOR
REVISIONS.
THIS CHECKLIST IS BEING PROVIDED FOR THE EXPRESS PURPOSE OF ASSISTING OUR CUSTOMERS IN THE
REVIEW OF THESE SIP SHOP DRAWINGS AGAINST THE PLAN SET CURRENTLY ON FILE AND FOR ACCURACY
AND COMPLETENESS. THIS HELPS ENSURE THE QUALITY OF THE PRODUCT AND EASE OF CONSTRUCTION IN
THE FIELD. PLEASE FEEL FREE TO CONTACT YOUR PBS PROJECT MANAGER WITH ANY QUESTIONS OR
CONCERNS THAT MAY ARISE DURING THE REVIEW PROCESS.
INITIAL
________ CONFIRM WINDOW ROUGH OPENING LOCATIONS & DIMENSIONS
________ CONFIRM DOOR ROUGH OPENING LOCATIONS & DIMENSIONS
________ CONFIRM WALL PLATE HEIGHT DIMENSIONS
________ CONFIRM ROOF PITCHES
________ CONFIRM ROOF OVERHANG DIMENSIONS
________ CONFIRM BEAM SIZES AND LOCATIONS
________ CONFIRM DESIGN VALUE CRITERIA (THIS PAGE)
________ CONFIRM OVERALL WALL DIMENSIONS INCLUDING STEPS IN FOUNDATION IF APPLICABLE
________ CONFIRM FLOOR THICKNESS AND DIMENSIONS
________ CONFIRM SIP FLOOR PANELS HAVE SOLID BLOCKING AT POINT LOADS
________ DENOTE ANY CUSTOM ELECTRICAL CHASE LOCATIONS WITH DIMENSIONS
________ SIGN THE SIGNATURE BLOCK IN LOWER RIGHT CORNER OF THIS SHEET
ANY AND ALL DISCREPANCIES RELATED TO SIPS ON SITE ARE THE RESPONSIBILITY OF OWNER UNLESS THERE
IS A DIFFERENCE BETWEEN FABRICATED SIPS AND SIGNED SIP SHOP DRAWINGS. PBS HOLDS FIRST RIGHT OF
DECISION TO REPLACE, REPAIR OR PAY FOR REPAIR OF ALL PRODUCTS IN DISCREPANCY WITH FINAL SIP
SHOP DRAWINGS.
SHEET- 001 COVER SHEET
SHEET- 002 INSTALLATION GUIDE
SHEET- 003 SIP PERSPECTIVE VIEWS
SHEET- 004 SIP FRAMING ITEMS
SHEET- 101 SIP PLAN
SHEET- 601 DETAILS
SHEET- 602 DETAILS
AS A SUPPLIER OF MATERIALS ONLY, PBS ACCEPTS NO RESPONSIBILITY
FOR ERRORS IN DESIGN, ENGINEERING, OR DIMENSIONS.
OWNER/AGENT (ARCHITECT, CONTRACTOR, AND/OR INSTALLER) SHALL
VERIFY ALL DIMENSIONS AND SIZES, AND BY SIGNING THESE PLANS, THE
OWNER TAKES FULL RESPONSIBILITY FOR THEIR ACCURACY. I
UNDERSTAND THAT THIS STRUCTURE IS TO BE ASSEMBLED IN
ACCORDANCE WITH THE PREMIER SIPS RESOURCE MANUAL.
GENERAL NOTES
1. THESE SIP SHOP DRAWINGS ARE BASED ON THE INFORMATION FURNISHED TO PREMIER BUILDING SYSTEMS (PBS). PROPER
INSTALLATION OF OUR PRODUCT SHOULD BE DONE BY A LICENSED CONTRACTOR. IT IS THE CONTRACTOR'S RESPONSIBILITY TO
COMPLY WITH ALL APPLICABLE FEDERAL, STATE, AND LOCAL CODES, REGULATIONS, AND SAFETY MEASURES.
2. PBS'S SIP SHOP DRAWINGS ARE FOR ILLUSTRATION PURPOSES AND SIP ASSEMBLY. AS SUCH, THESE SIP SHOP DRAWINGS ARE NOT TO
BE CONSIDERED A REPLACEMENT FOR THE EXPERTISE OF AN ARCHITECT OR ENGINEER, NOR THEIR DRAWINGS. THESE SIP SHOP
DRAWINGS EXCLUDE ANY DESIGN OF SITE, FOUNDATION, MECHANICAL, ELECTRICAL, OR PLUMBING. SIP SHOP DRAWINGS ARE TO BE
USED IN CONJUNCTION WITH ARCHITECTURAL AND STRUCTURAL DRAWINGS. IF ANYTHING IS NOT CLEAR OR THERE ARE QUESTIONS
THEY SHOULD BE IMMEDIATELY DIRECTED TO THE ARCHITECT OR ENGINEER OF RECORD.
3. PBS MAKES EVERY EFFORT TO SUPPLY COMPLETE SIP LAYOUT DRAWINGS FROM THE ORIGINAL ARCHITECTURAL AND / OR STRUCTURAL
DRAWINGS PROVIDED TO US. IT IS THE RESPONSIBILITY OF THE CONTRACTOR OR OWNER TO CHECK AND VERIFY ALL DIMENSIONS,
NOTES AND DETAILS ON THE SIP SHOP DRAWINGS FOR COMPATIBILITY WITH THE ARCHITECTURAL AND OTHER CONSULTANTS'
DRAWINGS AND EXISTING CONDITIONS PRIOR TO COMMENCEMENT OF WORK. SIPS ARE FABRICATED PER THESE SIP SHOP DRAWINGS.
ANY DISCREPANCIES OR MISSING ITEMS IN THESE SHOP DRAWINGS SHOULD BE NOTED.
4. SHOULD ANY DISCREPANCIES OR OMISSIONS BE FOUND, THE CONTRACTOR OR OWNER MUST NOTIFY A PBS REPRESENTATIVE IN
WRITING, AS SOON AS POSSIBLE SO THAT CORRECTIONS CAN BE MADE BEFORE SIP FABRICATION BEGINS. CONTRACTOR SHOULD
LOOK THROUGH THE PLANS CAREFULLY TO ENSURE THAT ALL ASPECTS OF THE SIP PACKAGE CAN BE CONSTRUCTED THROUGH THEIR
PREFERRED MEANS AND METHODS PRIOR TO SIGNING OFF ON THE SIP SHOP DRAWINGS.
5. THE CONTRACTOR OR OWNER SHALL NOTIFY PBS IN WRITING OF ANY CHANGES TO THE SITE AND FIELD CONDITION WHICH MAY
AFFECT THE SIP LAYOUT, PRIOR TO THE START OF SIP FABRICATION.
6. IT IS THE CONTRACTOR'S OR OWNER'S RESPONSIBILITY TO PROVIDE A LEVEL AND SQUARE FOUNDATION TO ENSURE A GOOD FIT OF
THE PBS SIPS. PREMIER BUILDING SYSTEMS DOES NOT ASSUME RESPONSIBILITY FOR ANY VARIANCES FROM THE FINAL SIGNED PANEL
DRAWING AND SPECIFICATIONS OR ADJUSTMENTS REQUIRED RESULTING FROM THE CONDITIONS ENCOUNTERED ON THE JOB SITE.
7. THE DETAILS ON THE DRAWINGS MAY NOT BE ALL INCLUSIVE. SIPS MUST BE INSTALLED PER THE PREMIER SIPS RESOURCE MANUAL.
PLEASE REFER TO THE RESOURCE MANUAL DURING INSTALLATION.
8. SOME DIMENSIONS CAN NOT BE VERIFIED UNTIL CONSTRUCTED. THEREFORE PBS TAKES NO RESPONSIBILITY FOR FIELD
FABRICATION. SOME FIELD FABRICATED AREAS MAY HAVE BEEN HIGHLIGHTED ON THE SIP SHOP DRAWINGS BUT MAY NOT BE
LIMITED TO ONLY THOSE AREAS.
9. IT IS THE BUILDERS RESPONSIBILITY TO DETERMINE ALL MATERIALS NECESSARY FOR SIP INSTALLATION. THIS INCLUDES VERIFYING
THAT THE MATERIALS PBS WILL BE PROVIDING PER THE CONTRACT OF SALE ARE ADEQUATE FOR THE PROJECT AND SOURCE ANY
ADDITIONAL MATERIALS REQUIRED FOR SIP INSTALLATION THAT ARE NOT PROVIDED BY PBS. ALL DIMENSIONAL OR ENGINEERED
LUMBER, STEEL, ETC. USED FOR ANY PURPOSE AND NOT NOTED ON THE SHOP DRAWINGS, SHALL BE SUPPLIED BY OTHERS. REQUIRED
SUPPORT BEAMS, COLUMNS, DIMENSIONAL LUMBER AND HEADERS NOT NOTED ON THE SHOP DRAWINGS MUST BE DESIGNED AND
SUPPLIED BY OTHERS.
10. SIP WALL AND/OR ROOF LAYOUTS INCLUDE LOCATIONS OF FACTORY ELECTRICAL CHASES AS INDICATED IN THE LEGEND BELOW.
ADDITIONAL "CUSTOM" ELECTRICAL CHASES MAY BE ADDED FOR A FEE. ALL FIELD CUTS, INCLUDING ELECTRICAL AND PLUMBING
CHASES, MUST BE IN ACCORDANCE WITH THE PREMIER SIPS RESOURCE MANUAL, OR PRE-APPROVED BY PBS.
11. OWNER IS RESPONSIBLE FOR VERIFYING ALL SIP SHOP DRAWING DIMENSIONS TO ENSURE COMPLIANCE WITH ARCHITECTURAL AND
STRUCTURAL DRAWINGS. OWNER MUST "RED-LINE" DIMENSIONS ON SIP SHOP DRAWINGS WHICH NEED TO BE REVISED. IF
APPLICABLE, INDICATE WHICH END OF THE DIMENSION WILL BE RELOCATING. UNCHECKED DIMENSIONS MAY RESULT IN THE NEED
FOR FIELD FABRICATION.
12. PBS ACCEPTS NO RESPONSIBILITY FOR CONSTRUCTION, ARCHITECTURE, OR ENGINEERING.
13. EXECUTION OF WORK FOR THE SIP PACKAGE MAY REQUIRE COORDINATION WITH OTHER TRADES (I.E. ELECTRICIAN, HVAC,
WINDOW/DOOR MANUFACTURER, ETC...). THIS COORDINATION IS THE RESPONSIBILITY OF THE CONTRACTOR.
14. ALL ELEVATIONS DRAWN ARE VIEWED FROM THE

EXTERIOR UNLESS OTHERWISE NOTED.
15. WHEN BUILT PROPERLY A SIP BUILDING PROVIDES A TIGHT ENVELOPE. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO ENSURE
THAT THE SIP STRUCTURE IS PROPERLY VENTILATED TO ENSURE PROPER AIR QUALITY AND HUMIDITY LEVELS.
16. IT IS THE CONTRACTOR'S SOLE RESPONSIBILITY TO ENSURE THAT ALL SPLINES ARE PROPERLY SEATED INTO THE SIP RECESSES AND
COMPLETELY SEALED WITH PREMIER SEALANT PER PREMIER SIPS DETAILS. VOIDS BETWEEN SPLINE JOINTS ARE NOT ACCEPTABLE IN
A PROPER SIP INSTALLATION. ONLY USE EXPANDING SPRAY FOAM WHERE INDICATED WITHIN THE PREMIER SIPS DETAILS, INCLUDING
BUT NOT LIMITED TO, PENETRATIONS, LIFTING HOLES, ELECTRICAL BOXES, TOP OF SIP WALL/ROOF CONNECTIONS, ETC.
17. THE CONTRACTOR IS RESPONSIBLE TO DETERMINE THE PROPER WEATHER BARRIER (I.E. BUILDING WRAPS, FLASHING, ROOF
UNDERLAYMENT, ETC..) TO DRY IN THE BUILDING ENVELOPE.
18. YOU MAY EXPERIENCE DIMENSIONAL VARIANCES FROM THE CONSTRUCTION DRAWINGS AS SIPS ARE ASSEMBLED HAVING GAPS AT SIP
JOINTS AND ADDITIONAL MISCELLANEOUS CONSTRUCTION VARIABLES SUCH AS FABRICATION TOLERANCES, LUMBER POST THICKNESS
VARIANCES, ETC. MINOR FIELD CUTTING THE SIPS TO CONFORM WITH THE APPROVED DESIGN MAY BE REQUIRED TO ENSURE THAT
THE TOTAL WALL OR ROOF ASSEMBLY IS PER THE CONSTRUCTION DRAWINGS. PBS WILL ADD GAPS AS INDICATED ON SIP LAYOUTS
BETWEEN PANEL JOINTS IN THE SHOP DRAWINGS (TYPICALLY 1/8" GAP).
19. CONSULT YOUR PBS SALES REPRESENTATIVE OR PROJECT MANAGER IF FIELD MODIFICATIONS TO THE SIPS IS REQUIRED DUE TO
DEVIATION FROM THE APPROVED SIP SHOP DRAWINGS FOR ANY REASON.
EXP.
SEISMIC:
ROOF LOAD
ENGINEERING DATA
PSF
PSF
PSF
MPH
TOTAL LOAD:
DEAD LOAD:
LIVE LOAD:
PSF
PSF

XX
PSFLIVE LOAD:
WIND SPEED:
FLOOR LOAD
TOTAL LOAD:
DEAD LOAD:

XX
XX
XX
XX
XX
XX
XX
XX

PREMIER SIPS ROOF TYPE
EPS A5.50A ZB
6 PREMIER SIPS FLOOR TYPE
EPS A5.50A ZB
6
ELEVATION:

XX

001

NOTE:
FOR CALIFORNIA PROJECTS, YOUR
CALIFORNIA INSIGNIAS ARE STAPLED
TO THE RECESS OF THE SIP
HOHM INC
Nikolas Woods
LEGEND/ABBREVIATIONS